SUOER SW-21 Ophthalmic Ultrasound is a comprehensive diagnostic equipment that allows the following four different probes to be connected and used simultaneously:
A-Scan, B-Scan, Pachymeter Scan, 3D B-Scan and UBM.
The main function is the diagnosis of ophthalmic intraocular diseases, which indicates the location of the lesion, the extent of the morphology and the surrounding problem.
It measures corneal thickness, anterior chamber depth, lens thickness, axial length, calculates the diopter of the lens to be implanted, and calculates corneal structures, lesions, angles, ciliary body, iris, anterior chamber, etc. examines the anterior segment of the eye, including
It can also diagnose lens opacity, retinal detachment, intraocular tumors and other intraocular diseases, and is widely used in glaucoma, eye trauma and ciliary diseases.
It has the features of high measurement accuracy, fast measurement, simple and convenient operations, portability, wide scanning range, high resolution, high geometric position accuracy.
The high-speed, efficient, modular design is perfect for solving any Physician’s need.
10 MHz B Scan Ultrasound
Ultra-quiet standard B probe with 10MHz frequency
Sector Scan
Multiple continuous zoom, Real-time magnification
Axial ≤0.3mm, Lateral≤0.2mm resolution
60mm image depth
30dB-105dB Gain adjustment
53⁰ Scan angle
256 Grayscale
Length, circumference and area measurement
Video recording of 100 photos, video output in AVI and JPG formats
Display Mode: B, B + B, B + A, A
10 MHz A Scan Biometrics
10MHz, A Scan probe with internal fixation LED
40mm measuring depth
±0.05mm resolution
Anterior chamber depth, lens thickness, vitreous length, axial length and mean
Phakic / Aphakic / Dence / Puseudophakic (Acrylic, Silicone, PMMA) eye type selection
6 IOL calculation formulas SRK-II, SRK-T, HOFFER-Q, HOLLADAY, BINKHORST-II, HAIGIS
Mean and standard deviation calculation
10 Scan results for each eye
Calculate 4 lenses simultaneously for each eye
20 Mhz P Scan Pachymeter
Detection of corneal thickness with 20MHz Pachymeter Probe and 45° angle.
150 micron – 1500 micron. measuring range
5 micron resolution
Central Single Measurement or 25 point Map Mode measurement and average value
Possibility of getting reports from the built-in printer for map or single measurement
Ability to calculate the corrected IOP value, taking into account the corneal thickness, by entering the IOP value
50MHz UBM
50MHz UBM Probe
Comprehensive Sector Scan Mode, Distortion-free, sulcus to sulcus imaging
16mm x 9mm; 10mm x 6.5mm scanning ranges
40μm Vertical 40μm Horizontal resolution
1024 Lines, 15μm screen resolution between each line
UBM, UBM + A display
It has a special independent 50μm ultrasonic amplification system, system performance that makes the anterior segment image clearer
Can work on PC or Lap Top computer with Windows operating system